ACOTOM PROCESS / UNIQUE TECHNOLOGY : Electronic decoding of 2 coded and independent magnetic fields => You can't defraud him with a magnet. Insensitive to external magnetic fields => allows the use of INOX316L housing Can be decoded through a steel plate up to 6mm thick => the sensor can be protected (embedded in the machine structure)
HYGIEN DESIGN to avoid the adhesion of bacteria and facilitate cleaning :
Security level | PLc, Cat 1 without Safety Relays (up to PLe, cat 4 with safety relay) |
Supply voltage | 20VDC at 30VDC |
Security contact | 2 potential-free NO contacts 1A/48V |
Auxiliary contact | 1 NF (PNP) |
Operating temperature | -25°C at +60°C |
Scanning range | Sao = 6 mm (guaranteed activation distance) Sar = 8 mm (assured breaking distance) |
Materials / IP | STAINLESS STEEL316L with LASER marking IP69K (front) - IP67 (rear and connector) |
Connecting | PUR cable (50cm) + M12/8 pin connector |
LED | Red = door open |
Diametre | M30 |